- Order goods
- Description and specifications
Description
Specifications
Local heat treatment unit in low case.
Weight, kg
350
Number of channels
3
Case
The rigid frame case with powder painting and an additional varnish covering. Removable panels on all sides of the case provide easy access. Power sockets on the rear panel. Special wheels for manual moving. Reinforced base for transportation.
Transformer
- Air cooling - Insulation class - H - Voltage on the primary winding - 50 Hz, 3 outlets of 360, 380, 400V
Power at 100% cycle, kW
38
Working voltage (secondary winding)
0 - 30 - 60V
Nominal power of each channel
10,8 kW 4 heaters
Primary current at 100% cycle, A
55
Safety
-Stop button -Contact voltage and spacedaptransfer 30V -Individual protection (optional)
Contact voltage referring to grounding
30V is maximum voltage with quick release via built-in safety shutdown device 300 mA
Temperature register
6-channel, electronic. Record on chart paper of 100 mm (optional - paperless recorder)
Thermocouple inputs
6 type K thermocouple panel connectors
Type of controller
TC-60 or TC-80 with special software in case of separate control for each channel. P250A or P256A by request in case of control of all channels by one program
Visual control
- Neon indicator - Ammeter 200А
Manual control
Power controllers on each channel
Dimensions LxWxH, mm
1450 x 650 x 1000
Order code | Description | Add to Cart |
---|---|---|
750023 | Local heat treatment unit RT38-3 |
|