- Order goods
- Description and specifications
Description
Specifications
12-channel unit RT100-12 power of 100kW is suitable for simultaneous processing of large number of small diameter joints.
Weight, kg
750
Number of channels
12
Case
- Hard frame case with powder painting and additional varnish coating - Power sockets on the back panel - Special wheels for manual move - Reinforced base for loader transportation - There are 4 eye-bolts on the top panel to move by crane
Transformer
- Air cooling - Insulation class - H - Voltage on the primary winding - 50 Hz, 3 outlets of 360, 380, 400V
Power at 100% cycle, kW
100
Working voltage (secondary winding)
0 - 30 - 60V
Nominal power of each channel
8,1 kW 3 heaters
Primary current at 100% cycle, A
160
Safety
- Control of working temperature of transformer with forced shutdown in case of overload or short circuit -Stop button -Contact voltage respective to the grounding 30V -Individual protection of each channel through a fuse -Safety shutdown device 300mA (optional) -Control voltage stabilization unit (optional)
Contact voltage referring to grounding
Maximum voltage is 30V with quick-release tripping via built-in protective shutdown device 300 mA
Temperature register
12-channel, electronic. Record on chart paper of 180 mm (optional - paperless recorder) (2 recorders optional)
Thermocouple inputs
12 or 24 type K thermocouple panel connectors
Type of controller
TC-60 or TC-80 with special software in case of separate control for each channel. P250A or P256A by request in case of control of all channels by one program
Visual control
- Neon indicator - Ammeter 200А
Manual control
Enegry regulator on each channel
Dimensions LxWxH, mm
1340 x 900 x 1680
Order code | Description | Add to Cart |
---|---|---|
750100 | Local heat treatment unit RT100-12 |
|